top of page

CKP-Serie

CAN Keypad

Description:

CAN & LIN multiplexed products and switches providing solutions to the On/Off Highway Industry.

Compliant with SAE J1939 CAN standards, the CKP-Series is a customizable keypad featuring laser etched legends and up to three dimmable LED function lights per button, which also offer diagnostic feedback by blinking if there is a fault.

Sealed to an IP69 protection level, the CKP-Series can be installed inside or outside the cab making it ideal for any on/off-highway application. Its low profile design affords a seamless dashboard look and can be mounted either vertically or horizontally.

The CKP-Series offers significant advantages over traditional electromechanical switches such as 1,000,000 actuation cycles, reduced wire harnessing, and easy installation.

icon_leaf.png

Operating Voltage

Designed for 12/24 Volt Systems

Minimum 8 VDC

Maximum 32 VDC

EMC

Transient immunity: ISO 11452-2,100 V/m, 20 MHz to 2,000 MHz

Class A per ISO 11451-1

Conducted Transient immunity: ISO 7637-2:2004, Annex A Table A2 ( for 24V systems),

Class A

Endurance 

Each button functions for at least 1,000,000 total actuations

Software

CAN Protocol: CAN 2.0b type interface as defined by SAE J1939

IConnector

Mates to the Deutsch DT-Series Connector

Mounting

10-32 Mounting Studs (2x)

Sealing Protection

Fully Sealed IP68 front panel

Fully sealed IP68 back panel when connected

Thermal

-40 degrees C to + 85 degrees C

Solar Radiation

IEC 60068-2-5, procedureB, 10 cycles Total irradiation per cycle = 22.4 kWh/m

Shock and Bump

IEC 60068-2-27, Shock 500m/s2 11milliseconds, Bump 400 m/s2 6 milliseconds 600 cycles 

Vibrations

IEC 60068-2-6, Swept sine wave section 8.2 5-500 HZ 20 cycles 5g acceleration

Chemical Resistance 

IEC 60068-2-74, Class B Engine oil, Diesel, Hydraulic oil, Ethylene Glycol, Urea Notrogen

Liquid Lime, NPK Fertiliser, Ammonia, Calcium Chloride, Brake fluid

Corrosion Resistance

IEC 60068-2-52, Test Kb, Severity lvl 4

Weathering/Cracking Resistance

ASTM D1171-99, method A, 72 hours